Product line Class 0 oil-free centrifugal compressors for your plant air and utility air solutions

Inlet conditions

Flow demand

Recommended arrangement lowest machine count that covers the demand within each frame's published capacity

Compressor room list edit to customize your compressor room with multiple compressor frames, including an addition to an existing site

MachineQtyFrame sizeFlow per machine (optional)Flow
Planned flow —
Demand —
Remaining —

Want a PDF of this layout arrangement for record?

Want the power consumption and budgetary price for this arrangement?

Flow coverage is only half the decision. An FS-Elliott application engineer will run your arrangement against your operating profile and send back total power consumption and a budgetary price.

Frame capacity reference

FrameMinimumMaximumPublished motor range (kW)

Confused about pseudo-mass flow versus volumetric flow? Struggling to convert between imperial and metric units?

AeroSwap simplifies compressor flow rate conversions, providing fast, precise results across any units and operating conditions, all in one place. By factoring in gas type, operating parameters, and system losses, AeroSwap delivers clear, consistent data you can trust for accurate system design and equipment evaluations.

Step 1: Inlet conditions

Delivered flow accounts for leakage through seals and drains. The default reflects general industrial practice; enter the figure for your seal technology if you know it.

Step 2: Convert from

Step 3: Convert to

—

Explore further

Compare flow figures like for like

The same compressor can be described by very different numbers. Enter a flow below as the baseline. Each row shows that same machine stated another way, using the inlet conditions from Step 1, and how far the number moves from the baseline. A higher number in this table does not mean more useful air.

Stated asValueUnitChange from baselineWhy it differs
Baseline
SCFM, dry (delivered) at 14.7 PSI (A), 60°F, 0% RH SCFMbaseline The recommended basis: dry gas actually delivered to your process, at API 672 reference conditions.
Wet or dry basis
SCFM, wet (delivered), same referenceSCFM Counts the water vapour in the gas. Intercoolers and the dryer remove that water before the air reaches your process.
Reference condition definition
SCFM, dry (delivered) at 14.5 PSI (A), 68°F, 0% RHSCFM ISO 1217 and CAGI Option 2 reference. Same air, stated at a warmer, lower-pressure standard cubic foot.
SCFM, dry (delivered) at 14.7 PSI (A), 68°F, 36% RHSCFM CAGI Option 1 reference. A warmer standard cubic foot that also contains water vapour.
SCFM, dry (delivered) at 14.7 PSI (A), 70°F, 0% RHSCFM A warmer reference temperature, so each standard cubic foot holds less air.
Flow type
ICFM, inlet volumeICFM Volume entering the compressor at your inlet conditions, before leakage. It rises on hot, humid days although the machine delivers no more air.
FAD, delivered volumecfm Delivered volume at your inlet conditions. Comparable between suppliers only when both use identical inlet conditions.
Mass flow at the inlet, including moisturelb/min Shown for reference. A different unit, so no percentage applies.
Losses left out
SCFM, dry, calculated without the inlet air filter pressure drop Often overlookedSCFM Assumes the inlet air filter causes no pressure loss, overstating how much air the compressor takes in.
SCFM, dry, with leakage ignoredSCFM Presents inlet flow as delivered flow, ignoring the loss through seals and drains.

The recommended basis for comparing compressors

Compare compressors on SCFM, dry, delivered (or Nm³/min, dry, delivered), stated at the same reference condition for every supplier, with API 672 conditions (14.7 PSI (A), 60°F, 0% RH) as the recommended standard.

Dry, because water vapour is removed by the intercoolers and the dryer and never reaches your process. Delivered, because leakage through seals and drains is air you pay to compress but cannot use. The same reference condition, because changing the definition of a standard cubic foot changes the number without changing the machine.

Flow units explained

Flow can be expressed in three ways. Volume flow is the space the gas occupies, which changes with pressure, temperature and humidity. Mass flow is the quantity of gas itself, unaffected by those conditions. Pseudo-mass flow is a volume converted to an agreed reference condition, so that it behaves like a mass flow; change the reference condition and the number changes with it.

ICFM: inlet cubic feet per minute

The volume of gas entering the compressor, after the inlet filter, at the actual inlet pressure, temperature and humidity. ICFM has meaning only together with the inlet conditions it was calculated at.

ACFM: actual cubic feet per minute

The actual volume at a stated point in the system, at the pressure and temperature at that point. The term is often used loosely for either inlet or delivered volume, so always ask which point and which conditions are meant.

FAD: free air delivery

The volume actually delivered, after leakage, expressed at the compressor inlet conditions. FAD from two suppliers is comparable only when both used identical inlet conditions.

m³/min: cubic meters per minute

The metric unit of volume flow. On its own it does not say whether the flow is measured at the inlet or delivered, so confirm which.

SCFM: standard cubic feet per minute

Delivered flow converted to a reference condition of pressure, temperature and humidity, on a wet or dry basis. Both the basis and the reference condition must be stated for an SCFM figure to be meaningful.

Nm³/min or Nm³/hr: normal cubic meters

The metric counterpart of SCFM. "Normal" conditions vary between 0°C, 15°C and 20°C, and between 1.013 bar and 1 bar, so the reference must be stated.

Reference conditions

Each of these is a recognized standard, which is why every SCFM or Nm³ figure must state its reference condition.

StandardReference conditionWhere you will see it
API 672 (5th edition, 3.1.47)14.7 PSI (A), 60°F, 0% RHRecommended standard for comparing compressors
ISO 1217 (4th edition, Annex F)1 bar (A), 20°C, 0% RH
(14.5 PSI (A), 68°F)
Screw and other displacement compressor data sheets
CAGI BL 300-2022 (4.4.16, Option 2)14.5 PSI (A), 68°F, 0% RHSame conditions as ISO 1217
CAGI BL 300-2022 (4.4.16, Option 1)14.7 PSI (A), 68°F, 36% RHCompressed air data stated with humidity in the reference
DIN 13431.01325 bar (A), 0°C, 0% RHThe most common meaning of "normal" in Nm³
ISO 134431.01325 bar (A), 15°C, 0% RHNatural gas and fuel gas measurement
NIST normal temperature and pressure1.01325 bar (A), 20°CLaboratory and US government references

Realistic inlet conditions: dew point

The dew point is the temperature at which air becomes saturated and its moisture starts to condense. It measures how much water the air actually holds. Temperature and relative humidity together set the dew point: the same moisture gives a high relative humidity on a cool morning and a low one on a hot afternoon.

Compressor specifications sometimes combine the highest expected inlet temperature with 100% relative humidity. In nature these do not occur together: 100% humidity is reached only after the air has cooled well below its daily maximum. API 672 (5th edition, 6.1.2.2) notes that dew points above 92°F (33°C) seldom occur anywhere. Sizing a compressor for such conditions assumes far more moisture than the site will ever see, leading to oversized impellers, larger drivers, more cooling capacity and a higher price, with no gain in reliability. Specify a realistic relative humidity at the rated temperature, or a dew point that reflects the site.

The table shows the dew point for each combination of temperature and relative humidity. Yellow and orange cells are hot and humid but realistic: sites in regions such as India and Southeast Asia regularly see them in summer, and sizing a centrifugal compressor for them ensures it delivers its flow on the hottest days. Red cells reach or exceed 92°F (33°C), conditions that rarely if ever occur.

Get the PDF

Your capacity plan downloads straight away. Let us know who you are so we can follow up if you need anything.

Request power consumption and budgetary price

Your arrangement and inlet conditions are sent with this request. An FS-Elliott application engineer replies with the numbers.